Delta UPS - RT Series, Single Phase, 1/2/3 kVA

RT Series, Single Phase, 1/2/3 kVA

 

INTRODUCTION

Reliable power with greater energy-saving features

The Amplon RT 1-3kVA series is an online double-conversion UPS providing consistent sine-wave power to your critical equipment. It supports personal computers, networks, servers, VoIP, and telecommunications. The Amplon RT 1-3kVA series features an output power factor of 0.9 and best-in-class AC-AC efficiency of up to 94% resulting in greater energy savings. An optional external battery pack can be connected for longer backup time to keep your applications safe and running smoothly at all times

Applications:

Application areas for Delta RT series UPS 1-3kVA by Delta

FEATURES

Availability
True online double-conversion topology and zero transfer time to battery ensure high reliability.
Watch-dog design of DSP (Digital Signal Processor) increases reliability.
Cold-start capability provides temporary battery power when the utility power is out.
Fan failure detection alerts users to failed fans.
Hot-swappable batteries ensure continuous operation even when batteries are being replaced.
Optional external battery pack for easy scaling of longer backup time.
Operation temperature tolerance up to 50°C ensures critical loads’ continuity
Green & Low TCO
High output power factor of 0.9 provides more real power to critical loads.
High input power factor (pf > 0.99) and low harmonic distortion (iTHD < 5%) save upstream investment.
Up to 94% AC-AC efficiency and 97% efficiency in ECO mode result in marked energy cost savings.
Wide input voltage range reduces the chance of using the battery and extends battery life.
Intelligent battery management sustains battery life and performance.
Fan speed control by load level maximizes efficiency and reduces audible noise.
Flexibility
Load segment control allows less-critical loads to be disconnected during blackouts and saves battery runtime for important loads.
Convertible rack and tower configuration in 2U size cabinet.
Excellent local communications through rotatable LCD display.
Intelligent management software connectivity via RS232 or USB port.

TECHNICAL SPECIFICATIONS

Model
[RT-3K]: 3kVA/ 2.7kW
Input
Nominal Voltage
200*/208*/220/230/240 Vac
Voltage range
175 ~ 280 Vac (full load)
120 ~ 175 Vac (70 ~ 100% load)
Frequency
40 ~ 70 Hz
Power Factor
> 0.99 (full load)
Current Harmonic Distortion
< 5%
Output
Power Factor
0.9
Voltage
200*/208*/220/230/240 Vac
Voltage Regulation
± 1% (linear load)
Frequency
50/60 Hz ± 0.05 Hz
Voltage Harmonic Distortion
< 2% (linear load)
Overload Capability
< 105%: Continuous
105% ~ 125%: 1 minute
125% ~ 150%: 15 seconds
Receptacle
3K]: IEC C13 x 6, IEC C19 x 1
Efficiency
AC-AC
3K]: Up to 94%
ECO Mode
3K]: Up to 97%
Receptacle:
IEC C13 x 6, IEC C19 x 1
Battery
Battery Voltage
[RT-3K]: 72 Vdc
Typical Backup Time**
3K]: 7 minutes
Charge Current
3K]: 2A
Recharge Time
3 hours to 90%
Audible Noise
[RT-3K]: < 46 dBA
Display
LCD display and LED indicators
Display
LCD display and LED indicators
Communication Interfaces
SMART Slot x 1, RS-232 Port x 1, USB Port x 1, REPO x 1
Conformance
EN 62040-1, CE, TISI, RCM, EAC
Dimensions (W x D x H)
[RT-3K]: 440 x 610 x 89 mm
External Battery Pack
[RT-3K]: 440 x 610 x 89 mm
Weight
UPS
[RT-3K]: 28 kg
Environment
Operating Temperature
0 ~ 50°C***
Relative Humidity
5% ~ 95% (non-condensing)