Vertiv Liebert GXT5 On-Line 16kVA/16kW 230V LCD PF1.0, 9U, Extended Run Rack/Tower Online Ups

550,000.00

Description

Liebert GXT5 750VA – 20kVA

Vertiv™ Liebert® GXT5™ UPS is a single phase, online double conversion UPS solution which offers robust power outage protection and continuous power conditioning in a compact and flexible deployment system. Liebert GXT5 is ideally suited to protect critical infrastructure in both centralized and edge network applications. Liebert GXT5 comes with various models ranging from 750VA to 20kVA and in both tower or rack form factor.

GXT5-20KIRT9UXLN.VERTIV Uninterruptible Power Supplies (UPS) VERTIV Uninterruptible Power Supplies (UPS) Supplier, Supply, Install |

UPS VERTIV LIEBERT GXT5-20KIRT9UXLN 20KVA/20KW (01201987)

Best Suited For:
  • Banking, Financial and Insurance
  • Data Center/Colocation/Hosting
  • Education
  • Government
  • Healthcare
  • Manufacturing
  • Retail and Wholesale
  • Telecom
  • Transportation

Specs

Ratings (VA/W )16,000 VA / 16,000W
Dimensions and weight
Dimensions (mm) Unit, W×D×H 430 × 630 × 394
Unit Weight (kg) 135.2
Input AC Parameters
Operating Frequency, Nom 50 or 60 Hz (Factory Default is 50 Hz )
Input Voltage 200/208/220/230/240 VAC Single Phase+ neutral + PE (or)
345/360/380/400/415 VAC Three phase + neutral + PE
Operating Voltage Range Without Battery
Operation (VL-N) 176 to 288 VAC (100 to 176 VAC with power derating)
Input Frequency Without Battery Operation 40 to 70 Hz
Output AC Parameters
AC-AC Efficiency Up to 95.9%
User-configurable Voltage 200/208/220/230/240 VAC
Factory Default Voltage 230 VAC
Frequency 50 Hz
Waveform Pure Sinewave
Main Mode Overload ≤ 105% continuous ; 105 to 125% for 5 minutes;
125 to 150% for 60 seconds; > 150% minimum 200 ms
Internal Battery
Charger Current 2.25 A (default), maximum 13 A
Type Valve-regulated, non-spillable, lead acid
Qty x V x Rating 32 x 12V x 9.0 AH

Back-up Time at Full Load 3.5
Back-up Time at Half Load 9.5
Bypass Protection Limits
Upper-limit Selections + 10%, + 15%, + 20%; default + 10%.
Lower-limit Selections – 10%, – 15%, – 20%; default – 15%
Disable-bypass operation When the input frequency prevents synchronous operation
General
Operating Temperature Full power up to 40 ºC (up to 50 ºC with derating)
Storage Temperature -20 to +60 °C ( contain batteries will be from -15 to 40 °C)
Relative Humidity 0 to 95% non-condensing
Operating Elevation Up to 3,000 m (9,842.5 ft) at 25°C (77°F) without derating
Audible Noise <58 dBA
Safety UL-1778 (Fifth Edition), C-UL listed, IEC 62040-1: 2008 (First Edition) + Am 1:2013,
EN 62040-1:2008+A1:2013
EMI/EMC/C-Tick EMC IEC/EN/AS 62040-2 2nd Ed (Cat 2 – Table 6); FCC Part 15 (Class A), CISPR22 Class A (RFI)
ESD IEC/EN EN61000-4-2, Level 4, Criteria B
Radiated Susceptibility IEC/EN EN61000-4-3, Level 3, Criteria A
Electrical Fast Transient IEC/EN EN61000-4-4, Level 4, Criteria B
Surge Immunity IEC/EN EN61000-4-5, Level 4, Criteria A; ANSI C62.41 Category B
Transportation ISTA Procedure 1E

 